BS EN 1363: Fire resistance test

Overview of BS EN 1363:

The BS EN 1363 standard consists of several parts, but the main part of the standard is BS EN 1363-1: 2012, which provides the general principles and definitions related to fire resistance testing.

Key Points of BS EN 1363-1: 2012:

  1. Scope:
    • This standard applies to the determination of the fire resistance of materials and structural elements used in buildings and civil engineering works.
    • It covers a wide range of elements, such as load-bearing walls, floors, doors, and windows, as well as non-load-bearing partitions and ceilings.
  2. Fire Resistance Test:
    • The test measures the ability of a structure or material to withstand fire exposure and prevent the spread of fire or smoke.
    • The resistance is typically assessed in terms of:
      • Load-bearing capacity (R): The ability to carry load during a fire.
      • Integrity (E): The ability of the element to maintain its physical integrity and prevent fire and smoke from passing through.
      • Thermal Insulation (I): The ability to limit the temperature rise on the unexposed side of the material or structure.
  3. Test Conditions:
    • Fire Exposure: The fire is usually created in a furnace that simulates realistic fire conditions. The furnace temperature is controlled and gradually increases according to a standard temperature-time curve (such as the “standard fire curve”).
    • The element to be tested is exposed to this fire under controlled conditions, and measurements are taken to evaluate its performance.
  4. Test Procedure:
    • A sample of the material or element is placed in the fire test furnace.
    • During the test, the temperature is measured at various points on the unexposed side of the material to assess thermal insulation.
    • The integrity of the structure is checked by observing whether cracks or holes form in the material, allowing flames or smoke to pass through.
    • The load-bearing capacity is tested by applying a load to the structure and ensuring it remains intact under fire conditions.
  5. Performance Criteria:
    • Fire Resistance Rating: After the test, the performance is classified in terms of how long the material or structure can withstand the fire before failure. The rating is typically provided in hours (e.g., 30 minutes, 1 hour, 2 hours).
    • A classification like “REI” (R for load-bearing, E for integrity, and I for insulation) is often used, with each letter being associated with a time period.
  6. Reporting:
    • The results of the test are documented and analyzed. The report includes detailed information about the performance of the test specimen in relation to its load-bearing, integrity, and insulation properties during the fire exposure.

Other Parts of BS EN 1363:

  • BS EN 1363-2: This part of the standard specifies the test methods for fire resistance of structural elements, including partitions and structural glazing.
  • BS EN 1363-3: Focuses on testing for fire resistance of roof coverings.

The BS EN 1363 series is crucial for determining fire-resistance ratings for building components and ensuring that structures can perform adequately in the event of a fire, protecting both occupants and property.